Water-to-water chillers. TWS series from Thermex.
Main characteristics:
- 34 sizes with cooling capacity from 39 to 450 kW;
- Scroll compressors;
- Operating range of coolant temperatures at the chiller outlet from -14 to +20°C;
- Casing treatment with zinc-containing primer, powder coating RAL 7035;
- Integration into a common control system with Smart Thermex Energy (STE) condenserless chillers;
High efficiency:
- Plate copper-soldered stainless steel evaporators with low hydraulic resistance;
- Electronic expansion valve (EEV);
High reliability:
- Compressor with external thermal protection and crankcase heating;
- Built-in voltage parameter monitoring relay protects the chiller from incorrect phasing and other possible supply voltage failures;
- Built-in high and low pressure relays;
- Built-in high and low pressure gauges;
- Dismountable filter on the freon circuit for ease of maintenance;
- Thick-walled copper pipe;
- Pressure sensor discharge;
Convenient and quick installation:
- Unloading/loading by forklift or crane;
- Compact housing 800 mm wide;
- Simple first start-up;
Wide control system capabilities:
- Controller with 7-inch touch panel;
- Chiller mnemonic diagram on the main screen;
- Simple and user-friendly interface in Russian;
- Accident log with time;
- Basic equipment for connecting to a cloud service for remote control and maintenance (Ethernet connection required);
- Convenient service menu for testing all actuators in manual mode;
- Support for the ModBus protocol (over TCP IP) in the basic configuration;
- Control of cooling capacity by:
- coolant temperature;
- evaporating pressure (compressors are switched off when it drops);
- superheating (compressors are switched off when there is a large superheat);
- discharge pressure (compressors are switched off when the pressure increases);
- Control of external THM hydraulic modules;
- Control of remote TED drycooler;
Basic equipment:
- CL - cloud service via Ethernet;
- PI - built-in pressure gauges;
- EEV - electronic expansion valve;
- TS7 - controller with touch panel;
- B13 - thermal insulation of the refrigeration circuit;
- MP - electronic condensation pressure control;
- SP - stainless steel hydromodule piping;
- H0 - without hydromodule insulation;
- FR - freon filling;
Additional options:
- HM1 - built-in hydromodule with one pump;
- HM2 - built-in hydromodule with two pumps;
- GSM - GSM modem for connection to the cloud service;
- TS0 - remote 7-inch operator panel;
- PB - UPS for controllers;
- CS - cascade control of up to 16 chillers;
- PA - protective panels of the housing;
- PLN - noise insulation (housing + compressors);
- VS - vibration isolators;
- BP - hydromodule piping made of black steel;
- ET - membrane tank;
- H13 - thermal insulation thickness hydromodule/tank;
- FCP - frequency converter of hydromodule pumps;
- N2 - nitrogen filling;
| General characteristics | |
| Refrigerant | R410A |
| Thermal standard 1 | |
| Coolant inlet temperature | 7 °С |
| Coolant temperature at the chiller outlet | 12 °С |
| Condenser inlet water temperature | 40 °С |
| Cooling capacity | 332 kW |
| Electric power of compressors | 110 kW |
| Temperature characteristics | |
| Operating temperature range ambient air | From -5°С to +43°С |
| Operating temperature range coolant at the outlet of the chiller | From -14°С to +20°С |
| EER (temperature standard 1) | 3.01 |
| Compressors | |
| Compressor type | Spiral |
| Number of compressors | 6 |
| Number of contours | 2 |
| Capacitor | |
| Water flow through the condenser | 76 m3/hour |
| Hydraulic resistance of the capacitor | 72 kPa |
| Capacitor connection diameter | DN 150 |
| Evaporator | |
| Water flow through the evaporator | 57 m3/hour |
| Hydraulic resistance of the evaporator | 41 kPa |
| Evaporator connection diameter | DN 125 |
Water-to-water chiller Thermex TWS-26-354
- Brand: Thermex Energy
- Product Code: TWS-26-354
- Availability: In Stock
-
Price on request